Two Storey House Ballymore Eustace, Co. Wicklow
Project Description
- 280 m2 house build in 2007
- Originally heated by oil boiler.
- Two underfloor heating zones
- One DHW zone
- System was sized to provide all space heating and DHW requirements. Existing oil boiler was decommissioned. Existing “Systemlink” manifold and all controls were decommissioned and plant room fully rebuild.
MasterTherm system features
- Heat pump type: 1 x BoxAir 37i
- Heating output: 5 – 17 kW
- SCOP Space heating: 4.6
- Fast recovery 250 Litres DHW tank with built inn 100 litres thermal storage tank.
- Online access and monitoring with 7 Years warranty affording peace of mind for the home owner. The systems data is being continually logged and identified to optimise performance and efficiency.