Geothermal Heat Pump Replacement – Limerick

Original system prior to the MasterTherm heat pump retrofit

  • 131 m2 detached house with two zones of radiators
  • Originally heated by external oil boiler
  • Heat controlled by timers
  • 3 kW of Photovoltaic solar panels

Solution with MasterTherm heat pump

  • Heat pump type: 1 x BoxAir 26 inverter
  • Heating output: 9 kW
  • SCOP heating: 4.3

House is being heated at constant temperature of 21 Degrees. Client has online access via app. System is connected to the internet. Client thus benefits with a 7 Year warranty on the entire heat pump system.

Two room terminals pAD were installed to allow controlling each zone on weather compensation bases allowing heat pump to “self learn” about minimum heating water conditions which maximise efficiency of the heat pump and comfort for the end user.

PV panels partly provide electricity for the heat pump

IMG 5710