Two Storey House Tallanstown, Co. Westmeath

Project Description

  • 260 m2 house build in 2009
  • Originally heated with oil boiler.
  • Two radiator zones
  • One DHW zone
  • System was sized to provide all space heating and DHW requirements. Existing oil boiler was decommissioned. Existing “Systemlink” manifold with circulation pumps was reused for space and domestic hot water distribution minimising cost of the project.

MasterTherm  system features

  • Heat pump type:    1 x BoxAir  37i
  • Heating output:    5 – 17 kW 
  • SCOP Space heating:    4.3
  • Fast recovery 300 Litres DHW tank
  • Online access and monitoring with 7 Years warranty affording peace of mind for the home owner. The systems data is being continually logged and identified to optimise performance and efficiency.

Both radiator heating zones are controlled by the MasterTherm control system on weather compensation bases.

tallan dom 1